Viewing Report 1st June 2020 – IMT3

20:25 – 00:15

Dome once again open to cool down

Solved FoV for Lodestar guider on 12″

Now guiding on star to West side of mount around 0 degrees Dec and near the Meridian to see if problem reoccurs, graph looks ok but there is a slight regular pattern of error.

Slewed to M92 which is a glob currently at Alt +74, Dec 43 and on the East side of the mount where I had issues last night. I plate solved the image.

The auto focus run looked good

Found guide star by moving M92 slightly off centre. Now guiding. All looked good for a short while. So each section of PHD2 graph is 25 points, so when you have 100 points selected there are 4 sections of the graph. This mean each section/column represents own my case 250 seconds as I expose for 10 seconds, so just over 4 minutes per section. So the errors I saw last night were about 12mins apart. This cannot be the work gear as it has a cycle of 2min 29sec. This is from the latest Paramount manual for the MEII.

  • Tracking at the sidereal rate, one revolution of the worm takes 149.6 seconds (2 minutes 29 seconds).
  • The right ascension gear has 576 teeth.
  • The declination gear has 475 teeth.

The error I am seeing is about 4mins. I cannot continue imaging as every few frames are trailed.

Viewing Report 31st May 2020 – IMT3

18:01 – 01:09

Opened dome early to cool down at 6pm.

The first thing to do were Flats for Ha first for the previous night but also for use tonight. I completed this at 22:15

At 22:31 I performed focus run on Luminance which came in at position 59841 with HFR 4.77.

I started an image run as soon as the Pelican Nebula (IC5067) was above the neighbours house. I have set a run of 10 x 600s and 20 x 300s Ha subs guided with the new PHD2 settings to prove the 12″ now works from 1 night to another. Then we can try the Esprit on the next clear night. The guiding at first looked okay.

Good initial guiding

The resulting image looked very good too

300s Ha guided Pelican
300s Ha guided zoomed no trailing
600s Ha Pelican guided
600s guided zoomed no trailing

After about 5 frames I suddenly ran into a problem the guiding looked like this

There were large movements in the Dec and the RA would not return to centre. Soon enough SGPro stopped imaging and tried to settle the guider and then further complained about not being able to settle. So I temporarily changed the Hysterisis from 10 to 15 to see if this would get the star back. It did, well just.

The RA axis returns to the centre after quite some time. Is this possibly seeing related or is there something mechanical amiss with the setup?

I did notice the problem one more and then went off to bed left it running 01:09 leaving the possible bump in the worm to resolve itself.

bump in the worm?

Addendum – So got up this morning and the scope had continued its travel across the heavens. I looked at SGPro and it finished the sequence without any problem. I then looked at PHD2 and expanded the time to include the maximum span possible as it had been trying to guide after loosing the star (I have check boxed Enable Star Mass Detection in the hope this fixes it) and I noticed a problem, which is the recurring South then North oscillation which I now need to investigate as that is the cause of loosing an image due to the star moving. It looks for all the world to be on the worm gear. I will set about measuring the PEC tonight and see if I can see it. It may of course be from when I adjusted the work due to another problem I had and it may not be quite right. I will also ask on the forum.