Viewing Report 29th May 2020 – IMT3

21:05 -2:56am

Currently cooling dome since 8pm.

Dome open to cool down

Logged in at 22:43 to slew to Pelican IC 5067

Esprit 120 FHR was 1.99 for Lum and 2.54 on the Ha

Focused on Deneb , 30 seconds exposure produced HFR 2.23

Deneb – 30 seconds in Ha
Solve and Sync

Solve and sync completed on Deneb in Ha

The focus point for Ha was 6217

Now for a quick frame and focus, 30 seconds exposure

30 seconds Ha on Pelican as Frame and Focus test

That looked good, next up was to see if we can image for 5 minutes unguided and see what the resulting image looked like

300s Ha Pelican

Again the resulting image looked very good and no star trails

Clear skies with -18℃ measured by the Infrared sensor on the AAG Cloud-Watcher.

AAG Infrared sensor read -18c so zero clouds

I then tried a 10min image but got clear trailing.

Star trailing at 10 minute exposure

So I set the guiding up with PHD2, went out to the dome and created a dark library as this was not done. I then set about training the guider and then set it running, initially with a 4 second exposure. The resulting guide graph looked a bit bumpy. The ASC looked very clear this evening which was the first time in a while. You could see stars to the left hand edge of the image which is normally obscured by cloud.

ASC Clear skies

We decided to run the guiding assistant in PHD2 and see if there were any changes that needed to be made. It came up with some suggestions including redoing the calibration and changing the calibration step size from 1600 to allow more steps in the calibration, in this case I changed to 1200 to try and go from 3 steps per axis to 8, however I got to 6 steps and this seemed good enough. When I then reran the guiding assistant I no long got the error about calibration. I did have a few suggestions as seen below which I applied.

Guiding Assistant recommendations

So the changes made still have not allowed 10mins images, they are still trailed. So that I do not waste any further time this evening I captured 5 minute images instead of 10 minutes and I will relook at the guiding next week when the Moon get brigheter.

At 1:38 we gave up on guiding and switched to 12″, Autofocus on Lum, 63384 HFR 5.4. Took some 5 minute and a single 10 minute frame guided, scope trailing ?

There were three scopes on the Pelican Nebula (IC5070/IC5067) tonight as GingerGeek was imaging with the Tak FSQ85 from his back garden.

3 Different image scales from tonight

Finished to go to bed at 2:56 am, GingerGeek finished the session by taking flats, warming up the CCD and bringing the scope indoors just after 3am.

Rough stack of Ha (5nm) 10×600 seconds, -15℃ From the FSQ85
ASC and Summer Triangle

Viewing Report – Cinco de Mayo 2020

Moon 96% Waning.

Our TOSA Manual needs updating now that we have replaced the HiTechAstro Deluxe Cloud Sensor with the Lunático AAG CloudWatcher cloud detector.

New Screens to get familiar with:

.

.

.

.

.

.

Initially I was unable to open the shutter of the dome. Thinking I’d forgotten to reset the HiTechAstro relay I soon realised I had to figure out why the AAG_Cloudwatcher software was reporting Unsafe. GingerGeek spotted that the Brightness level looked like a sawtooth and should settle after a few minutes, which it appeared to do and the dome shutter opened successfully.

Following on from my previous observing session on 1st May when clouds interrupted play just as I was completing a Guiding Assistant run in PHD2, I started tonight’s session with a quick look at Venus before it set below our horizon and then had another go at running the Guiding Assistant in PHD2 for the OS 12″ / Tak FS-102 combination, with the Tak as the guider for the Officina Stellare.

Venus in Ha (because it’s so bright).

Crop

As the Tak has an Alnitak Flip Flat attached to it I added it to the profile I’ve created for the OS12 and Tak combination so that the panel can be opened to allow light through to the camera 🙂

Guiding Assistant completed successfully and values applied for RA MnMo, Dec MnMo and Dec Backlash compensation.

.

Y scale = 2, Target Radius = 1.5

Sequence running for 2, 5, 7, 10, 12 and 15minutes.

2, 5,& 7 minutes exposures ok but trailing beginning to show at 10 minutes, quite evident at 12 minutes and very evident at 15 minutes.

Added 8 and 9 minutes to sequence, but both of these show signs of stars trailing.

Started a sequence of 24 x 5 minute exposures.

Aborted at frame 20 as the NGC3628 was now below the horizon.

The image has drifted and NGC 3628 has not remained fixed in the frame, so we still have issues with guiding as that is almost certainly the source of the drift.

02:22 Slew to M5, just off centre.

Slew to HIP 74975 to centre and focus.

De-selected guider.

02:57 Slewed to M5 and started a sequence of 24 x Lum and 8 x R,G,B 120s frames.

Sample Luminance frame:

04:08 SQM graph has started to droop. Was 18.2 before 4am, now down to 18

04:10 ASC image brightening quickly

04:15 SQM 17.54

04:24 Camera Warming Up

Disconnected Guider

Telescope Parked and disconnected.

Dome Parked (shutter closed) and disconnected

De-humidifier on.

Camera Power Off

04:30 I’m off to bed