Imaging Report 15th-16th December 2022

As it was a work night and Dave was working I was imaging from the back garden and not the dark site. I started late in the evening and had issues sorting out the autofocus in NINA which meant I was even later than I had planned.

Using the OptoLong L-Pro filter and the native camera driver (not ASCOM) :

QHY268C Nina Native Mode

The target was decided by Dave as M31 (Andromeda Galaxy), I decided on 120 second exposures at -15℃, gain 0 and offset 30 (Photographic Mode). I finally started to capture data at 19:55 when M31 had already transited 45 minutes earlier.

M31 single sub (stretched) via NINA Imaging Session

I believe the dark shadow to the left is the QHY OAG prism, I may have to reduce it’s depth in the light path or rotate it 45 degrees so it sits on the long horizontal axis.

Once M31 had reached approximately 50 degrees altitude and was starting to set in the West my guiding started going awry especially in RA. I put this done to either balance issues or cable snagging so that’s something I need to look at in the future.

After shutting down earlier than I thought due to the guiding issue and the pending rising Moon I decided to do my darks, flats and dark flats. However my Pegasus Flatmaster refused to connect to NINA so I decided to fix and complete this task on a different day.

I only managed to capture 62 subs which totals just over 2 hours. I was hoping to get at least 6 hrs for a single session and something approaching > 12 hours which means I will need several more nights to capture my required amount of data for M31.

Not a great first outing but given I hadn’t imaged in ages this was expected. I can honestly say that although a OSC coupled with the new harmonic mounts such as the ZWO AM5/Pegasus Nyx are very convenient as part of a lightweight holiday travel setup. OSC also is easier processing but still I can say I’m not a total fan due to the loss of high frequency data, high HFR focus issues and in the case of the QHY268C the noise banding issue which although appears to be removed by darks etc still is unnerving.

Update (17/12/2022)

Have resolved my Flatmaster 120 panel issues but I feel I’m better off with a fully controllable fixed panel instead of a manual panel so I will look into that.

My Darks, Flats and Dark Flats are now done (25 of each) all performed at -15℃ to match this session temperatures but there is still not enough actual data to start processing.

Equipment Check-up

So after ages I’m planning to perform some imaging after being challenged by Dave to produce a OSC image of M31 with the QHY268C that can be of print quality.

The first step was upgrading all the necessary software to make sure both the NUC and laptop would not be interrupted during my planned imaging session.

  • Windows10 latest Updates (Dec2022)
  • SGPro (4.2.0936)
  • NINA (2.1 HF1 Beta002)
  • ASTAP (2022.12.09)
  • ASCOM (6.6SP1)
  • Pegasus Ultimate PowerBox (1.6.1230.46)
  • iOptron commander (5.9.0.2)

The iOptron CEM60 mount hadn’t been updated in ages and it showed :

  • HandControllerV2 : 210106
  • MainBoard : 190716
  • RA board : 201005
  • DEC board : 190716

After performing the firmware update procedure, the mount was now showing the following levels :

  • HandControllerV2 : 220119
  • MainBoard : 211018
  • RA board : 211018
  • DEC board : 211018
  • Catalog : 150429

Of course I will need to perform a new zero mount position following the upgrade. Tonight I will also be changing the OpenPHD algorithm to PredictivePEC as described by Cuiv the LazyGeek :

https://www.youtube.com/watch?v=BfvmlR3It1o