Darkness Testing 20th June 2020 – IMT3

20:00 – 23:48

Tonight GingerGeek came over for a bit of social distancing friendly astronomy along with a bottle of Malbec wine. The idea was to calibrate the AAG, specifically when it goes from Very Bright to Light to Dark and at those points what the SQM value is along with the Sun’s position below the horizon. The AAG needs to get to 2100 which is dark, light is 5 and very light is 0.

The first time we noticed the values starting to change on the AAG brightness when it moved from its continuous reading throughout the day was at 21:47 when the Sun was -3.45 degrees below the horizon and the SQM was 10.15.

Within seconds the AAG read 9 and was already on Light vs Very Light and the Sun was now -3.54 degrees below the horizon and the SQM read 10.28.

It took almost half an hour for the AAG to get to dark. At 22:16 the AAG finally reached 2100, the SQM was at 13.97 and Sun was at -6.52 degrees below the horizon.

GingerGeek had also developed a new server for IMT3 to visualise some of the data from the observatory. The Grafana dashboard charts below show the data along with the Sun altitude.

New IMT3 Grafana dashboard

Looking at the last 24 hours shows the effect of the light nights on the SQM. The raised values after 4am went the value should be reducing or zero is the effect of a cat or bird covering the sensor. Also worthy of note is the sky temperature which shows the effect of cloud as the SkyTemperature increases. A truly clear sky would yield a value of -18℃ or better.

Shows the entire night

We also took darks on the ASC and applied them since we had never bothered to do it before. The shot below shows the before and after effect of applying the dark/bad pixel map. The whole image looks a lot cleaner and darker, although there seems to be some negative representation going on with dark pixels.

Before and after applying darks

The setting that needed to be changed in the ASC software took GingerGeek a while to find.

ASC Setting to apply darks

During the daytime the ASC looked awful but remote the darkframe reference file and just applying the badpixel map seem to be better. Tonight’s set of images will show if this is better or not.

The only other odd thing that happened tonight was the dome closed without the safety setting it off. Not sure why yet ……

Viewing Report 13th June 2020 – IMT3

23:31 – 04:02

So I opened the dome late this evening as it was not due to be clear. However an opening in the cloud meant I could test guiding again on the 12″, especially whilst it was light in the late Spring weeks.

The first job was as always to focus which brought me to a reading of 61944 at 19.83℃.

Focus run

Another small job was to sort the guider FoV out. I went ahead and used M92 to align the guider.

Aligning guider FoV using M92

The final FoV settings are here for completness.

FoV for guider

Set AS1600 to Gain and Offset 10 due to cluster being very bright and I needed to set a standard of 60 seconds minimum exposure. Gain 139 and Offset 21 gas saturated unless I selected 15 seconds, Gain 75 and Offset 12 saturated at 30 seconds so hence 10 and 10 which came in about 58k ADU.

I then performed a slew to a nearby star so I could centre the scope, there platsolve completed successfully and I updated TSX and the FoV for the 12″ with the new angle.

Platesolve

The first image of 60 seconds came down and was out of focus, I then realised changing the profile SGPro forgot the autofocus setting, so I had to stop the run, delete the images and set the original focus point then rerun.

M92 out of focus
M92 in focus

Next I ran a few images but then to my horror I had the same guiding issue, where the star moves being dragged up and down in a periodic way. I slewed elsewhere and tried again and the problem did not occur. I was near M92 and just East of the Meridian and quite high up. Not sure why that is a problem.

Near the Meridian

I could not resolve, I waited a while then performed a meridian flip and low and behold the problem went away, again not sure why. I still have this terrible noise coming from the RA motor/gear area. I decided to bite the bullet and take off various caps on the scope listening and looking inside. I decided it was not after all, the through the mount cabling but coming from the RA gear itself, so I looked for the MEII guide for removing the worm block and then followed the instructions to take off the RA cover.

RA gearing and belt noise

This gave me instant feedback on what the issue was, the belts driving the axis were making a noise. On looking through forums on Bisque.com I found a few people with similar issues and needing to grease the belts, they were told Lubriplate was a good grease. This is an American grease so I will find a similar here and then apply, I will ask Bob first for his suggestion.

So the night wore on and the LRGB frames of M92 I thought I would take whilst testing guiding progressed. At one point the imaging stopped due to cloud. I just caught the dome before it closed to change the safety sensor due to cloud. When it cleared it never really cleared, with the sky temperature reading about -14℃.

Not very clear

Nearing the end of the imaging session, I had caught about 15 frames of each of the filters.

Good guiding and imaging

The guider was behaving mostly with he odd funny jolt. By 3:30 am the sky was lightening very quickly.

3:30am and bright

By this time I had stopped guiding and imaging. I closed the dome, slewed the scope to the flat panel and proceeded to take a set of LRGB flats for Gain 10 Offset 0 and also Gain 139 and Offset 21 as request from the previous nights imaging.

Viewing Report 12th June 2020 – IMT3

22:09 – 02:02

ASC

It was unexpectedly clear this evening so I opened the dome late, so no cooling down.

Focus 60,279 Lum filter at 19.93℃

Autofocus run

Slewed to Arp 286 as I had seen on Flickr and wanted to see what it looked like in 12″. I noted I needed a new set of Darks for the Lodestar off axis guider after we had changed the driver recently, so I set about taking those with PHD2.

autoguider darks

The problem I then saw was no guide star in the FoV! I really need a rotator!!!!!

So I will image without the guider. The first image jumped as I realised the auto-guider was still on and trying to track nothing sending the mount this way and that. So I disabled and set about running 3 x LRGB for 300 seconds a piece

The first image was Luminance and looked ok, although bright due to high level cloud and no astronomical darkness this time of year. I also noted the mark on the filter caused by the LensPen! I won’t use that again. However I do expect that to come out with the flat so not too bothered. Also I could go clean it I just don’t want more dust on the filter so will leave until I have a reason to take the camera off again.

Arp 285 Luminance 300 seconds

For reference here is the luminance flat.

Luminance Flat showing Lenspen mark

Next up was Red filter for 300 seconds

Arp 286 Red 300 seconds

Then Green filter

Arp 286 Green 300 seconds

Then finally Blue filter.

Arp 286 Blue 300 seconds

So I left it to run for 3 x 300 seconds each filter. Meanwhile Mil Dave came online and opened his dome and we decided to go for a joint target to see how they compare. Given Arp 286 was below Dave’s hedge I mentioned the Coddington Nebula IC2574 which is actually a galaxy, being the object in my latest image from the travel rig with the Esprit120 and the comet passing. It has some interesting star clusters in it. We agreed on luminance and 300 seconds. Here is Dave’s result ….

Coddington Nebula by Mil Dave

Meanwhile the humidity kept rising

IMT3 environment gauges

At just gone midnight I finished the short run on Arp 286 and slewed to Coddington to catch up with Mil Dave. First I did a quick refocus as the temperature had dropped about 2℃ since I started.

refocus but note the point at 62,056

The refocus put me near but not near enough so I changed to 62,056 for a better HFR which worked. Then I went on to do Coddington and here is my result.

Coddington behind the tree from 12″

I had problems with unguided exposure, then had a problem finding a guide star, then the object was behind a tree!

So next I slewed to Mil Dave’s choice of object, here is Mil Dave’s image

Arp 214

I managed to find a guide star straight away and grabbed this

Arp 214

Notice my screen stretch is different hence the bright background. It is just a quick screen grab off the NUC. My turn to pick now, so went for several objects but all behind offending hedges at Mil Dave’s house. So I sent Dave off to choose one. He came back shortly with Arp 278. So off we set. Here is mine.

Arp 278

and of course Mil Daves….but no, he forgot to save it 🙁

So my object next, I selected one nearby to save the rather long dome rotation I just did, and the resulting loud noise when it jammed! I need to look at that. Meanwhile Mil Dave trundled his round manually. So I choose NGC 7331, also known as C30 and Herschel H53-1, so also on my list for the Herschel 400. This is what I got.

NGC 7331 12″

Meanwhile the cloud from the South East started to creep in and my daughter, who just came in even at this hour of 1:36 said it was foggy outside.

ASC Cloud coming

Dave’s grabbed the NGC 7331 below.

NGC 7331 Mil Dave

I was about to suggest a Sharpless object when the clouds rolled in enough for me to shut the dome. It was reading -4.8℃ sky temperature and the limit was less than 30 for overcast, so I manual overrode.

ASC Clouds

Just before it shut this is the image I got of SH2-126 which is impossible to see since it probably needs the Ha filter rather than luminance.

SH2-126 300s 12″ Luminance

Well a good night all round, given we thought it was going to be cloudy it was nice to come out and play with Mil Dave and go hunting faint fuzzies, so a goodnight from me and a goodnight from him ?

Viewing Report 2nd June 2020 – IMT3

20:28 – 00:30

After a day of checking the mount and spending some 3 hours resetting the RA and DEC cam stop and spring plungers I have come out to see if I have resolved the image or made it worse. I can still hear the squeaking of the cables in the Through the mount position as the worm turns so I do need to remove 1 or 2 of them to free it up. However I no longer hear the knocking, tapping and grinding of the Dec axis. I am also going to capture some PEC data for Tom on the Software Bisque forum to look at. GingerGeek with his usual smoking jacket turned up to assist from a distance.

Whilst trying to find a star we came across a galaxy, NGC 5646 H126-1, which looked very interesting for the 12″, so we will come back and image that at a later date. We are in a rush for the clouds as it is to cloud over by 11:30pm. What we need to do is disable PEC, disable TPoint and Protrack and the guider relays then point at a star and guide without applying any corrections as per page 147 of the MEII manual for 15 minutes.

I went out to the dome and set with the help of GingerGeek the camera on the back of the 12″ to as close to 0 degrees as possible, in our case 0.81 degrees after plate solving.

We slewed to a start neat declination 0 and close to the Meridian on the East side of the mount called Tycho 326:747 and at 22:37 started to look at the auto-guider settings. The star was at DEC +01° 34′ 10.909″ and RA 14h 45m 20.1920. The auto-guider log in question for tonight was “Autoguider.018.log”. The star looked good in the main ZWO ASI1600mm camera which we would use to guide and collect the data. We did notice as per the image below over 15 minutes the star drifting East, so the polar alignment is out. More importantly we got the 15 minutes of data in the log as the clouds started to roll in, as can be seen in the star brightness below.

Autoguiding in TSX

The resulting log file was read into the Sky’s PEC and the raw data shown below one we clicked ‘Fit’ on the data which scales it to this chart. The peak to peak was 0.7 arcsecs. We applied this to the mount –

Raw PEC data from log
Fitted and applied PEC data

Next whilst GingerGeek went off to get his beauty sleep…..he really needs it 🙂 I set about slewing to a bright star in the vicinity and calibrating the guider, since I had rotated the camera. The calibration was successful even though the RA looked slights odd as a fit. The different in the RA and Dec rate was potentially due to position on the sky and the error in the RA plotting data. I will go back and do another calibration next time it is clear.

Calibration in PHD2

I then slewed to M92, could not find a guide star very suitable so moved around a bit and then started to guide and see what the graph looked like. What surprised me was the the amplitude of the guiding was only 0.36 arcsecs which is really low and no guiding issues as I saw before. It looks like the adjustments to the spring plungers and cam stops may have been the cause and fix.

Guiding graph at +74 deg altitude and near M92

I performed a quick focus run whilst pausing the guiding and got 61836 and HFR 4.4 which is vert good for this scope.

Auto focus

Meanwhile the clouds from the North had started to drift in which was going to stop play 🙁

All Sky Camera

I managed to get a single frame and focus on M92 of 20s before the clouds stopped the guiding. So I shut up the dome, sent the logs to Software Bisque, or the chap on the forum who was kind enough to help and went off to bed.

M92 20s sub

Viewing Report 1st June 2020 – IMT3

20:25 – 00:15

Dome once again open to cool down

Solved FoV for Lodestar guider on 12″

Now guiding on star to West side of mount around 0 degrees Dec and near the Meridian to see if problem reoccurs, graph looks ok but there is a slight regular pattern of error.

Slewed to M92 which is a glob currently at Alt +74, Dec 43 and on the East side of the mount where I had issues last night. I plate solved the image.

The auto focus run looked good

Found guide star by moving M92 slightly off centre. Now guiding. All looked good for a short while. So each section of PHD2 graph is 25 points, so when you have 100 points selected there are 4 sections of the graph. This mean each section/column represents own my case 250 seconds as I expose for 10 seconds, so just over 4 minutes per section. So the errors I saw last night were about 12mins apart. This cannot be the work gear as it has a cycle of 2min 29sec. This is from the latest Paramount manual for the MEII.

  • Tracking at the sidereal rate, one revolution of the worm takes 149.6 seconds (2 minutes 29 seconds).
  • The right ascension gear has 576 teeth.
  • The declination gear has 475 teeth.

The error I am seeing is about 4mins. I cannot continue imaging as every few frames are trailed.

Viewing Report 31st May 2020 – IMT3

18:01 – 01:09

Opened dome early to cool down at 6pm.

The first thing to do were Flats for Ha first for the previous night but also for use tonight. I completed this at 22:15

At 22:31 I performed focus run on Luminance which came in at position 59841 with HFR 4.77.

I started an image run as soon as the Pelican Nebula (IC5067) was above the neighbours house. I have set a run of 10 x 600s and 20 x 300s Ha subs guided with the new PHD2 settings to prove the 12″ now works from 1 night to another. Then we can try the Esprit on the next clear night. The guiding at first looked okay.

Good initial guiding

The resulting image looked very good too

300s Ha guided Pelican
300s Ha guided zoomed no trailing
600s Ha Pelican guided
600s guided zoomed no trailing

After about 5 frames I suddenly ran into a problem the guiding looked like this

There were large movements in the Dec and the RA would not return to centre. Soon enough SGPro stopped imaging and tried to settle the guider and then further complained about not being able to settle. So I temporarily changed the Hysterisis from 10 to 15 to see if this would get the star back. It did, well just.

The RA axis returns to the centre after quite some time. Is this possibly seeing related or is there something mechanical amiss with the setup?

I did notice the problem one more and then went off to bed left it running 01:09 leaving the possible bump in the worm to resolve itself.

bump in the worm?

Addendum – So got up this morning and the scope had continued its travel across the heavens. I looked at SGPro and it finished the sequence without any problem. I then looked at PHD2 and expanded the time to include the maximum span possible as it had been trying to guide after loosing the star (I have check boxed Enable Star Mass Detection in the hope this fixes it) and I noticed a problem, which is the recurring South then North oscillation which I now need to investigate as that is the cause of loosing an image due to the star moving. It looks for all the world to be on the worm gear. I will set about measuring the PEC tonight and see if I can see it. It may of course be from when I adjusted the work due to another problem I had and it may not be quite right. I will also ask on the forum.